AC/DC clip-on ammeter

Bluetooth interface for transferring measured data

CAT III - 1000 V, CAT IV - 600 V

Large LCD display & large clamp opening
Fast and very precise measurement of voltage, current, resistance, capacitance, frequency, duty factor and contact temperature.
Product code: 083.043A
| AUTO-POWER-OFF | 30 min. |
| RESISTANCE | 500 Ω ± (1,0% ± 9), 5/50/500 KΩ ± (1,0% ± 5), 5 MΩ ± (2,0% ± 10), 50 MΩ ± (3,0% ± 10) |
| DIODE TEST | Test current/voltage ≤ 0.3 mA / Open circuit voltage < 2 V DC typica |
| MAX. POWER INPUT | AC current: 1000 A DC current: 1000 A |
| AC CURRENT | 50-60 HZ 500 A / 1000 A ± (2,5% ± 5) |
| DC CURRENT | 500 A / 1000 A ± (2,5% ± 5) |
| AC VOLTAGE | 500 mV / 5/50/500 V ± (1,0% ± 30), 1000 V ± (3,0% ± 8) |
| DC VOLTAGE | 500 mV / 5/50/500 V ± (1,0% ± 8), 1000 V ± (1,5% ± 3) |
| Capacitance | 500 nF ± (3,5% ± 40), 5000 nF / 50/500 μF / 5000 mF ± (5,0% ± 10) |
| FREQUENCY | 50/500 Hz / 5/50/500 kHz / 5/10 MHz ± (0,3% ± 2) |
| Duty cycle | 5%…95% ± (1,0% ± 2) |
| TEMPERATURE | -100°C…1000°C ± (1% ± 2,5°C), K-type |
| CONTINUITY TEST | Response threshold < 35 Ω + 5 Ω Test current < 0,5 mA |
| LCD | 0...50000 |
| OVERVOLTAGE CATEGORY | CAT III - 1000 V / CAT IV - 600 V |
| Pollution degree | 2 |
| OPERATING CONDITIONS | 5 ... 40°C, 80%rH, no condensation, max. altitude 2000 m |
| STORAGE CONDITIONS | -20 ... 60°C, 80%rH, no condensation |
| RADIO MODULE OPERATING DATA | Bluetooth LE 4.x interface |
| POWER SUPPLY | 1 x 6LR61 9V |
| DIMENSIONS | 76 x 230 x 40 mm |
| WEIGHT (incl. batteries) | 496 g |